TECHNICAL SPECIFICATIONS FOR LOCATOR AND TRANSMITTER
Sensitivity 5µA at 1 meter (33kHz)
Dynamic range 140dB rms/Hz
Selectivity 120dB/Hz
Depth accuracy
Line: ± 5% tolerance 4" to 10' (0.1m to 3m)
Sonde: ± 5% tolerance 4" to 23' (0.1m to 7m)
Maximum depth* Line: 20ft (6m) Sonde: 50ft (15m)
Locate accuracy ± 5%
Fault-Finding (FF) Diagnose cable sheath faults from short circuit to 2M using the
A-frame
Batteries Locator: 2 x D-cells (LR20) or rechargeable battery pack
Transmitter: 8 x D-cells (LR20) or rechargeable battery pack
Warranty 36 Months upon registration
Dynamic Overload Protection 30dB (automatic)
Compliance FCC, RSS 310 RoHS, Weee, CE
Weight Transmitter: 6lb (2.84kg) (including batteries)
9lb (4.2kg) (including accessories)
Locator: 4lb (1.87kg) (including batteries)
Environment IP54
Operating temperature range -4°F to 122°F (-20°C to +50°C)
In good conditions. *RD7000+ will locate to a depth of over 50ft (15m) but accuracy may be reduced.
Available separately.
Accessories
Large stethoscope
Live cable connector
High gain stethoscope
Plug connector
Small stethoscope
An RD7000+ to
address any utility...
Oil
Gas
Water
Rail
Power
Telecom/CATV